0

Gas Insulated Transmission Lines - GIL

Wiley - IEEE

Erschienen am 01.11.2011
CHF 138,00
(inkl. MwSt.)
UVP

Lieferbarkeit auf Anfrage

In den Warenkorb
Bibliografische Daten
ISBN/EAN: 9780470665336
Sprache: Englisch
Umfang: 384
Auflage: 1. Auflage
Einband: Gebunden

Beschreibung

Gas-insulated transmission lines (GIL) is an established high voltage technology used when environmental or structural considerations restrict the use of overhead transmission lines. With an overview on the technical, economical and environmental impact and power system implications of GIL, this guide provides a complete understanding of its physical design, features and advantages. The author illustrates how to evaluate when GIL would be the best solution during the planning sequence and how to apply GIL in the electricity power network. Other key features include: * operation and maintenance requirements with information on repair processes, duration, and different monitoring systems enabling the achievement of reliable and safe operation; * a wide variety of realized applications from across the world over the past 35 years, illustrating typical fields of application through descriptions of real projects that the author has worked on; and * future application possibilities in a smart transmission network, used for solving power transmission problems. This is an essential reference for engineers involved in planning and executing bulk power transmission projects overground, in tunnels or buried. It offers a concise summary of all areas of the subject and is the perfect aid for utility power engineers, consulting engineers and manufacturers worldwide.

Autorenportrait

InhaltsangabeForeword xiii Acknowledgements xv 1 Introduction 1 1.1 Changing Electric Power Supply 1 1.2 Advantages of GIL 4 2 History 7 2.1 Transmission Network Development 7 2.2 Historical Development of GIL 20 3 Technology 39 3.1 Gas Insulation 41 3.1.1 Free Gas Space 42 3.1.2 Insulators 42 3.1.3 GasTight Enclosure 44 3.1.4 Insulating Gases 46 3.2 Basic Design 65 3.2.1 Overview 65 3.2.2 Dielectric Dimensioning 68 3.2.3 Thermal Dimensioning 68 3.2.4 Insulation Coordination 68 3.2.5 Electrical Optimization 69 3.2.6 Transmission Network Studies 69 3.2.7 Gas Pressure Dimensions 70 3.2.8 HighVoltage Design Tests 70 3.2.9 Current Rating Design 72 3.2.10 ShortCircuit Rating Design 73 3.2.11 Internal Arc Design 74 3.2.12 Electromagnetic Current Forces Design 76 3.2.13 Mechanical Design 76 3.2.14 Integrated Overvoltage Protection 77 3.2.15 Particles 78 3.2.16 Thermal Design 79 3.2.17 Seismic Design 86 3.3 Product Design 93 3.3.1 Technical Data 93 3.3.2 Conductor Pipe 95 3.3.3 Enclosure Pipe 95 3.3.4 Size of Gas Compartment 97 3.3.5 Insulators 98 3.3.6 Sliding Contacts 100 3.3.7 Modular Design 100 3.3.8 Overhead Line Connection 103 3.3.9 Bending Radius 103 3.3.10 Joint Technology for Conductor and Enclosure 104 3.3.10.1 Flanged Joints 105 3.3.11 Corrosion Protection 112 3.3.12 OnSite Assembly Work 116 3.3.13 Monitoring 117 3.4 Quality Control and Diagnostic Tools 123 3.4.1 Quality of Parts 124 3.4.2 Quality of Processes 124 3.4.3 Partial Discharge Detection 125 3.4.4 HighVoltage Testing OnSite 126 3.4.5 Conclusion of Quality Control 130 3.5 Planning Issues 131 3.5.1 Network Impact 131 3.5.2 Reliability 139 3.5.3 Grounding/Earthing 141 3.5.4 Safety 141 3.5.5 Environmental Limitations 143 3.5.6 Electric Phase Angle Compensation 145 3.5.7 Loadability and Capability Overload 145 3.6 Specification Checklist 149 3.7 Laying Options 153 3.7.1 General 153 3.7.2 AboveGround Installation 154 3.7.3 TrenchLaid 159 3.7.4 TunnelLaid 160 3.7.5 Directly Buried 166 3.7.6 Directional Boring 182 3.8 LongDuration Testing 183 3.8.1 General 183 3.8.2 Tunnel Version 184 3.8.3 Directly Buried Version 197 3.8.4 LongDuration Test Results 215 3.9 Gas Handling 217 3.9.1 General 217 3.9.2 Gas Mixture Handling 217 3.9.3 Conclusion 219 3.10 Commissioning and On-Site Testing 221 4 System and Network 225 4.1 General 225 4.2 Line Constants of GIL 225 4.3 Transmission Losses 228 4.4 Operational Aspects 231 4.5 Ageing 234 4.6 Internal Arc Fault 235 4.7 Maintenance 236 4.8 Repair 237 4.9 Personnel Safety 237 4.10 Insulation Coordination 238 4.11 System Control 247 5 Environmental Impact 253 5.1 General 253 5.2 Visual Impact 253 5.3 Electromagnetic Fields 254 5.4 Gas Handling 267 5.5 Thermal Aspects 267 5.6 Recycling 268 5.7 Lifecycle Assessment 269 5.8 CO2 Footprint 269 6 Economic Aspects 273 6.1 General 273 6.2 Material Cost 273 6.3 Assembly Cost 275 6.4 Transmission Losses 276 6.5 Cost Drivers 277 7 Applications 279 7.1 General 279 7.2 Examples 280 7.3 Future Application 312 7.4 Case Studies 314 8 Comparison of Transmission Systems 323 8.1 General 323 8.2 GIL Features 323 8.3 Technical Comparison 324 8.4 Site Comparison 330 8.5 Soft Parameters 332 8.6 Economics 333 9 Power Transmission Pipeline 335 9.1 Feasibility Study 336 9.2 Offshore Wind Energy in Europe 339 9.3 Under Sea Tunnel System 339 9.4 Offshore and Onshore PTPTM Constructions 344 9.5 NextGeneration Technology 346 9.6 Offshore Environment 346 10 Conclusion 349 References 351 Index 361

Leseprobe

Leseprobe

Weitere Artikel vom Autor "Koch, Hermann"

Lieferbar in ca. 10-14 Arbeitstagen

CHF 70,00
inkl. MwSt.
UVP

Lieferbarkeit auf Anfrage

CHF 16,50
inkl. MwSt.
UVP

Lieferbar in ca. 5 Arbeitstagen

CHF 134,00
inkl. MwSt.
UVP

Lieferbar in ca. 10-14 Arbeitstagen

CHF 20,90
inkl. MwSt.
UVP

Lieferbar in ca. 5 Arbeitstagen

CHF 38,40
inkl. MwSt.
UVP

Lieferbar in ca. 5 Arbeitstagen

CHF 59,00
inkl. MwSt.
UVP
Alle Artikel anzeigen

Weitere Artikel aus der Kategorie "Technik"

Lieferbar innerhalb 36 Stunden

CHF 27,90
inkl. MwSt.
UVP

Lieferbar innerhalb 36 Stunden

CHF 177,00
inkl. MwSt.
UVP

Titel noch nicht erschienen

CHF 92,40
inkl. MwSt.
UVP

Lieferbar innerhalb 36 Stunden

CHF 46,30
inkl. MwSt.
UVP

Lieferbar innerhalb 36 Stunden

CHF 56,90
inkl. MwSt.
UVP

Lieferbarkeit auf Anfrage

CHF 70,00
inkl. MwSt.
UVP
Alle Artikel anzeigen